Assembled by diesel engine and Brushless alternator.
Three filters as standard, fuel and water separator as optional.
Radiator and fan with safety guard.
Single bearing alternator IP 23, Insulation Class H.
Heavy duty steel as base frame and 8hrs operation base fuel tank.
Automatic control panel and 3 poles circuit breaker, internal cable.
12V or 24V battery, battery wires.
Battery and float battery charger as standard supply scope.
Fuel level indicator in meter and panel
Comply with ISO and CE standards: ISO8528, ISO14000, ISO3046, GB755, BS5000, VDE0530, IEC34-1 etc.
SME series 750~2250KVA 380V~440V |
|||||||||
Model |
Standby power |
Rated power |
Oil consumption with 100% load |
Current |
Engine |
Dimension |
Weight |
||
kVA |
kWe |
kVA |
kWe |
L/h |
A |
Model |
L×W×H mm |
KG |
|
FESM625E |
750 |
600 |
625 |
500 |
139 |
950 |
S6R2-PTA-C |
3896×1400×1778 |
5278 |
FESM750E |
825 |
660 |
750 |
600 |
170 |
1140 |
S6R2-PTAA-C |
4060×1830×2110 |
5700 |
FESM1250E |
1375 |
1100 |
1250 |
1000 |
266 |
1900 |
S12R-PTA-C |
4390×2040×2217 |
9300 |
FESM1375E |
1500 |
1200 |
1375 |
1100 |
281 |
2090 |
S12R-PTA2-C |
4450×2040×2153 |
9300 |
FESM1500E |
1650 |
1320 |
1500 |
1200 |
308 |
2280 |
S12R-PTAA2-C |
4980×2192×3022 |
10450 |
FESM1690E |
1875 |
1500 |
1690 |
1350 |
310 |
2564 |
S16R-PTA-C |
5148×2250×2545 |
12600 |
FESM1875E |
2000 |
1600 |
1875 |
1500 |
418 |
2849 |
S16R-PTA2-C |
5218×2245×2608 |
13100 |
FESM2000E |
2250 |
1800 |
2000 |
1600 |
432 |
3039 |
S16R-PTAA2-C |
5700×2192×3390 |
13400 |
Pre-sale:
1.Provide pre-sale technical support
2.Help to dispose the machine house and provide suggestions for installation
3.Help to choose genset model, capacity and function
After-sale:
1.Electric connection commission and installation of equipment
2.Environment protection project
3.Residual heat utilization project
4.Fault remedy and difficulty problem explanation
Training
1.Onesite training of maintenance and operation
2.Technique upgrade training in the factory
3.Guidance and training in the factory
Auxiliary:
1.Genset room design, installation, and commissioning Environment protection and soundproof project, heat recovery project
2.Paralleling and synchronization (main power, genset power) project
Service:
1.Set up the client record, follow-up service and visit periodically
2.Provide the training to the operator of users periodically
3.Help the operation during holiday or special day
4.Technical support and spare parts support
5.Respond within 30mins after receiving the claim for repair from clients, the service person will be sent within 2hrs
6.Can manage the common fault within 2hrs, and severe malfunction in 8hrs