While using the "Client-Oriented" organization philosophy, a rigorous top quality command process, highly developed production devices and a potent R&D workforce, we normally provide high quality products, outstanding solutions and aggressive charges for , , , We'll do our greatest to fulfill your specifications and are sincerely searching ahead to developing mutual helpful small business marriage with you!
Factory Supplied Electric Cable Spools - Perforated steel strip PE pipe For gas – Fasten Detail:

Application

Perforated steel strip polyethylene composite pipe is made of cold-rolled strip steel and thermoplastics as raw materials, and porous thin-walled steel pipes formed by argon arc butt welding or plasma spiral welding are used as reinforcements. The outer and inner layers are double-sided composite thermoplastics. A new type of composite pressure pipe, Because the porous thin-walled steel pipe reinforcement is wrapped in continuous thermoplastic, this composite pipe not only overcomes the respective shortcomings of steel pipes and plastic pipes, but also has the rigidity of steel pipes and the corrosion resistance of plastic pipes. It is a solution for petroleum and chemical industries. It is an urgently needed pipeline of large and medium-diameter rigid pipes in the fields of pharmaceutical, food, mining, gas and other fields. It is also a revolutionary technological achievement to solve the main pipeline of construction and municipal water supply. It is a new type of composite pipeline in the 21st century.

Perforated steel strip PE pipe For gas (1)
Perforated steel strip PE pipe For gas (2)

Features

Hygienic performance
The hygienic index and safety of the perforated steel strip plastic composite pipe meet the requirements of GB9687 “Hygienic Standard for Polyethylene Molded Products for Food Packaging” and GВ/Т17219 “Safety Evaluation Standard for Drinking Water Distribution Equipment and on Equipment and Protective Materials”. It is the best substitute for galvanized pipe and cast-iron pipe.

Smooth inner wall and circulation performance
The inner wall of the mesh steel belt plastic composite pipe is very smooth, and the absolute roughness is only 1/20 of that of the steel pipe. The conveying capacity under the same conditions is about 30% higher than that of the steel pipe.

Perforated steel strip PE pipe For water supply (3)

Technical Parameters

Specification size, deviation and nominal pressure: meet the requirements of the Ministry of construction standard CJ/T181-2003

Nominal outer diameter and deviation

Nominal wall thickness and deviation

Out of roundness

Nominal pressure

Minimum S value

Length and deviation

Dn(mm)

En(mm)

Mm

Mpa

Mm

mm

50+0.5 0

4.0+0.5 9

1.0

1.0

1.5

6000+20 0

9000+20 0

12000+20 0

60+0.6 0

4.5+0.6 0

1.26

1.0

1.5

75+0.7 0

5.0+0.7 0

1.5

1.0

1.5

90+0.9 0

5.5+0.8 0

1.8

1.0

1.5

110+1.0 0

6.0+0.9 0

2.2

1.0

1.5

140+1.1 0

8.0+1.0 0

2.8

1.0

2.5

160+1.2 0

10.0+1.1 0

3.2

1.0

2.5

200+1.3 0

11.0+1.2 0

4.0

1.0

2.5

250+1.4 0

12.0+1.3 0

5.0

0.8

3.5

315+1.6 0

13.0+1.4 0

6.3

0.8

3.5

400+1.6 0

15.0+1.5 0

8.0

0.8

3.5

500+1.7 0

16.0+1.6 0

10.0

0.6

4.0

630+1.8 0

17.0+1.7 0

12.3

0.6

4.0

Note: The nominal pressure of the composite pipe is the maximum pressure allowed for the pipe to transport water at 20°С. If the temperature changes, the working pressure should be corrected according to the temperature pressure coefficient of different materials.

S value: the distance from the outer diameter of the reinforcement to the outer surface of the pipe.

Physical and mechanical performance requirements
Project Performance
Ring stiffness, KN/m2 >8
Longitudinal shrinkage (110°С, maintain 1h) <0.3%
Hydraulic test Temperature: 20°С; Time: 1h; Nominal pressure x2 Not broken
Temperature: 80°С; Time: 165h; Pressure: Nominal pressure x2x0.71 (reduction factor)
Burst pressure test Temperature: 20°С, burst pressure≥nominal pressure x3.0 Blasting
Oxidation induction time (200°С), min >20
Resistant to rapid stress expansion (80°С, 4.0Mpa)/h >1000
Weather resistance (after the pipe has received≥3.5GJ/m2 aging energy) Meet the requirements of items 2,3 and 4 in this table, and can maintain good welding performance

Product detail pictures:

Factory Supplied Electric Cable Spools - Perforated steel strip PE pipe For gas – Fasten detail pictures

Factory Supplied Electric Cable Spools - Perforated steel strip PE pipe For gas – Fasten detail pictures

Factory Supplied Electric Cable Spools - Perforated steel strip PE pipe For gas – Fasten detail pictures


Related Product Guide:

It adheres on the tenet "Honest, industrious, enterprising, innovative" to develop new items frequently. It regards buyers, success as its very own success. Let us produce prosperous future hand in hand for Factory Supplied Electric Cable Spools - Perforated steel strip PE pipe For gas – Fasten , The product will supply to all over the world, such as: Hyderabad, Frankfurt, Rotterdam, With a fully integrated operation system, our company has won a good fame for our high quality goods, reasonable prices and good services. Meanwhile, we have established a strict quality management system conducted in material incoming, processing and delivery. Abiding by the principle of "Credit first and customer supremacy", we sincerely welcome clients from home and abroad to cooperate with us and advance together to create a brilliant future.
  • On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Novia from Porto - 2018.06.19 10:42
    The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Priscilla from Austria - 2018.08.12 12:27
    Write your message here and send it to us